Vigabatrin
minimum sample volume required ~ 5ml
Test Code: VIG
Tube type: SST
Other acceptable tube types
Lithium heparin (pale green)
Special instructions
Sample should be collected immediately before oral dose.
Sent away
to Theraputic Drug Monitoring Unit, Chalfont centre for Epilepsy, Buckingham
Reference range
0.8 - 36
Units
mg/L
Turnaround Time
7
days
Department: Biochemistry